Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Front Immunol ; 13: 947021, 2022.
Artículo en Inglés | MEDLINE | ID: covidwho-2316385

RESUMEN

SARS-CoV-2 Omicron infections are common among individuals who are vaccinated or have recovered from prior variant infection, but few reports have immunologically assessed serial Omicron infections. We characterized SARS-CoV-2 humoral responses in an individual who acquired laboratory-confirmed Omicron BA.1.15 ten weeks after a third dose of BNT162b2, and BA.2 thirteen weeks later. Responses were compared to 124 COVID-19-naive vaccinees. One month post-second and -third vaccine doses, the participant's wild-type and BA.1-specific IgG, ACE2-displacement and virus neutralization activities were average for a COVID-19-naive triple-vaccinated individual. BA.1 infection boosted the participant's responses to the cohort ≥95th percentile, but even this strong "hybrid" immunity failed to protect against BA.2. Reinfection increased BA.1 and BA.2-specific responses only modestly. Though vaccines clearly protect against severe disease, results highlight the continued importance of maintaining additional protective measures to counteract the immune-evasive Omicron variant, particularly as vaccine-induced immune responses naturally decline over time.


Asunto(s)
COVID-19 , Vacunas Virales , Enzima Convertidora de Angiotensina 2 , Anticuerpos Antivirales , Vacuna BNT162 , COVID-19/prevención & control , Vacunas contra la COVID-19 , Humanos , Inmunoglobulina G , SARS-CoV-2 , Vacunación
3.
J Infect Dis ; 2022 Jun 07.
Artículo en Inglés | MEDLINE | ID: covidwho-2298463

RESUMEN

BACKGROUND: Longer-term humoral responses to two-dose COVID-19 vaccines remain incompletely characterized in people living with HIV (PLWH), as do initial responses to a third dose. METHODS: We measured antibodies against the SARS-CoV-2 spike protein receptor-binding domain, ACE2 displacement and viral neutralization against wild-type and Omicron strains up to six months following two-dose vaccination, and one month following the third dose, in 99 PLWH receiving suppressive antiretroviral therapy, and 152 controls. RESULTS: Though humoral responses naturally decline following two-dose vaccination, we found no evidence of lower antibody concentrations nor faster rates of antibody decline in PLWH compared to controls after accounting for sociodemographic, health and vaccine-related factors. We also found no evidence of poorer viral neutralization in PLWH after two doses, nor evidence that a low nadir CD4+ T-cell count compromised responses. Post-third-dose humoral responses substantially exceeded post-second-dose levels, though Omicron-specific responses were consistently weaker than against wild-type. Nevertheless, post-third-dose responses in PLWH were comparable to or higher than controls. An mRNA-1273 third dose was the strongest consistent correlate of higher post-third-dose responses. CONCLUSION: PLWH receiving suppressive antiretroviral therapy mount strong antibody responses after two- and three-dose COVID-19 vaccination. Results underscore the immune benefits of third doses in light of Omicron.

4.
Can J Kidney Health Dis ; 10: 20543581231160511, 2023.
Artículo en Inglés | MEDLINE | ID: covidwho-2287735

RESUMEN

Background: People living with chronic kidney disease (CKD) have been disproportionately affected by the coronavirus disease 2019 (COVID-19) pandemic, including higher rates of infection, hospitalization, and death. Data on responsiveness to COVID-19 vaccination strategies and immunogenicity are limited, yet required to inform vaccination strategies in this at-risk population. Objective: The objective of this study is to characterize the longitudinal serologic response to COVID-19 vaccination. Design: This is a prospective observational cohort study. Setting: Participating outpatient kidney programs within Ontario and British Columbia. Patients: Up to 2500 participants with CKD G3b-5D receiving COVID-19 vaccination, including participants receiving dialysis and kidney transplant recipients (CKD G1T-5T). Measurements: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgG antibodies (anti-spike, anti-receptor binding domain, anti-nucleocapsid) will be detected by ELISA (enzyme-linked immunosorbent assay) from serum or dried blood spot testing. In a subset of participants, neutralizing antibodies against novel variants of concern will be evaluated. Peripheral blood mononuclear cells will be collected for exploratory immune profiling of SARS-CoV-2 specific cellular immunity. Methods: Participants will be recruited prior to or following any COVID-19 vaccine dose and have blood sampled for serological testing at multiple timepoints: 1, 3, 6, 9, and 12 months post vaccination. When possible, samples will be collected prior to a dose or booster. Participants will remain in the study for at least 1 year following their last COVID-19 vaccine dose. Strengths and limitations: The adaptive design of this study allows for planned modification based on emerging evidence or rapid changes in public health policy surrounding vaccination. Limitations include incomplete earlier timepoints for blood collection due to rapid vaccination of the population. Conclusions: This large multicenter serologic study of participants living with kidney disease will generate data on the kinetics of SARS-CoV-2 immune response to vaccination across the spectrum of CKD, providing insights into the amplitude and duration of immunity conferred by COVID-19 vaccination and allowing for characterization of factors associated with immune response. The results of this study may be used to inform immunization guidelines and public health recommendations for the 4 million Canadians living with CKD.


Contexte: Les personnes atteintes d'insuffisance rénale chronique (IRC) ont été touchées de façon disproportionnée par la pandémie de COVID-19 ayant notamment présenté des taux plus élevés d'infection, d'hospitalisation et de décès. Les données sur la réactivité aux stratégies de vaccination de la COVID-19 et à l'immunogénicité sont limitées, mais elles sont nécessaires pour développer des stratégies de vaccination dans cette population à risque. Objectif: Caractériser la réponse sérologique longitudinale à la vaccination contre la COVID-19. Conception: Étude de cohorte observationnelle prospective. Cadre: Les programmes ambulatoires de santé rénale participants en Ontario et en Colombie-Britannique. Sujets: Jusqu'à 2 500 personnes atteintes d'IRC G3B-5D recevant un vaccin contre la COVID-19, y compris des patients suivant des traitements de dialyse et des receveurs d'une greffe rénale (IRC G1T-5T). Mesures: Les anticorps IgG anti-SARS-CoV-2 (anti-spike, anti-domaine de liaison au récepteur, anti-nucléocapside) seront détectés par ELISA à partir du sérum ou de taches de sang séché. Un sous-groupe de sujets participera également à l'évaluation d'anticorps neutralisants dirigés contre les nouveaux variants préoccupants. Des cellules mononuclées de sang périphérique seront prélevées pour établir un profil immunitaire exploratoire de l'immunité cellulaire spécifique au SARS-CoV-2. Méthodologie: Les sujets seront recrutés avant ou après toute dose du vaccin contre la COVID-19 et se soumettront à des prélèvements sanguins pour les tests sérologiques à 1, 3, 6, 9 et 12 mois post-vaccination. Lorsque possible, des échantillons seront prélevés avant l'administration d'une dose ou d'un rappel. Les sujets demeureront dans l'étude pendant au moins un an après leur dernière dose de vaccin contre la COVID-19. Points forts et limites: La conception adaptative de l'étude permet d'apporter des modifications planifiées fondées sur de nouvelles données ou des changements rapides dans les politiques de santé publique entourant la vaccination. Les résultats sont limités par l'absence de certains prélèvements sanguins antérieurs (point temporels) en raison de la vaccination rapide de la population. Conclusion: Cette vaste étude sérologique multicentrique menée auprès de personnes atteintes de néphropathie fournira des données sur la cinétique de la réponse immunitaire à la vaccination contre le SARS-CoV-2 dans l'ensemble du spectre de l'IRC. Elle fournira des informations sur l'amplitude et la durée de l'immunité conférée par la vaccination contre la COVID-19 et permettra de caractériser les facteurs associés à la réponse immunitaire. Ces résultats serviront à orienter les recommandations de santé publique et les lignes directrices en matière d'immunisation pour les quatre millions de Canadiens et Canadiennes qui vivent avec l'IRC.

5.
AIDS ; 37(5): 709-721, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: covidwho-2267958

RESUMEN

BACKGROUND: Limited data exist regarding longer term antibody responses following three-dose coronavirus disease 2019 (COVID-19) vaccination, and the impact of a first SARS-CoV-2 infection during this time, in people with HIV (PWH) receiving suppressive antiretroviral therapy (ART). We quantified wild-type-specific, Omicron BA.1-specific and Omicron BA.5-specific responses up to 6 months post-third dose in 64 PWH and 117 controls who remained COVID-19-naive or experienced their first SARS-CoV-2 infection during this time. DESIGN: Longitudinal observational cohort. METHODS: We quantified wild-type-specific and Omicron-specific anti-Spike receptor-binding domain IgG concentrations, ACE2 displacement activities and live virus neutralization at 1, 3 and 6 months post-third vaccine dose. RESULTS: Third doses boosted all antibody measures above two-dose levels, but BA.1-specific responses remained significantly lower than wild-type-specific ones, with BA.5-specific responses lower still. Serum IgG concentrations declined at similar rates in COVID-19-naive PWH and controls post-third dose (median wild-type-specific and BA.1-specific half-lives were between 66 and 74 days for both groups). Antibody function also declined significantly yet comparably between groups: 6 months post-third dose, BA.1-specific neutralization was undetectable in more than 80% of COVID-19 naive PWH and more than 90% of controls. Breakthrough SARS-CoV-2 infection boosted antibody concentrations and function significantly above vaccine-induced levels in both PWH and controls, though BA.5-specific neutralization remained significantly poorer than BA.1 even post-breakthrough. CONCLUSION: Following three-dose COVID-19 vaccination, antibody response durability in PWH receiving ART is comparable with controls. PWH also mounted strong responses to breakthrough infection. Due to temporal response declines, however, COVID-19-naive individuals, regardless of HIV status, would benefit from a fourth dose within 6 months of their third.


Asunto(s)
COVID-19 , Infecciones por VIH , Humanos , Formación de Anticuerpos , Vacunas contra la COVID-19 , COVID-19/prevención & control , Infecciones por VIH/complicaciones , Infecciones por VIH/tratamiento farmacológico , SARS-CoV-2 , Vacunación , Inmunoglobulina G , Anticuerpos Antivirales , Anticuerpos Neutralizantes
6.
Open Forum Infect Dis ; 10(3): ofad073, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: covidwho-2273426

RESUMEN

Background: Longer-term immune response data after 3 doses of coronavirus disease 2019 (COVID-19) mRNA vaccine remain limited, particularly among older adults and after Omicron breakthrough infection. Methods: We quantified wild-type- and Omicron-specific serum immunoglobulin (Ig)G levels, angiotensin-converting enzyme 2 displacement activities, and live virus neutralization up to 6 months after third dose in 116 adults aged 24-98 years who remained COVID-19 naive or experienced their first severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection during this time. Results: Among the 78 participants who remained COVID-19 naive throughout follow up, wild-type- and Omicron-BA.1-specific IgG concentrations were comparable between younger and older adults, although BA.1-specific responses were consistently significantly lower than wild-type-specific responses in both groups. Wild-type- and BA.1-specific IgG concentrations declined at similar rates in COVID-19-naive younger and older adults, with median half-lives ranging from 69 to 78 days. Antiviral antibody functions declined substantially over time in COVID-19-naive individuals, particularly in older adults: by 6 months, BA.1-specific neutralization was undetectable in 96% of older adults, versus 56% of younger adults. Severe acute respiratory syndrome coronavirus 2 infection, experienced by 38 participants, boosted IgG levels and neutralization above those induced by vaccination alone. Nevertheless, BA.1-specific neutralization remained significantly lower than wild-type, with BA.5-specific neutralization lower still. Higher Omicron BA.1-specific neutralization 1 month after third dose was an independent correlate of lower SARS-CoV-2 infection risk. Conclusions: Results underscore the immune benefits of the third COVID-19 mRNA vaccine dose in adults of all ages and identify vaccine-induced Omicron-specific neutralization as a correlate of protective immunity. Systemic antibody responses and functions however, particularly Omicron-specific neutralization, decline rapidly in COVID-19-naive individuals, particularly in older adults, supporting the need for additional booster doses.

7.
AIDS ; 37(5): F11-F18, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: covidwho-2239764

RESUMEN

OBJECTIVE: Limited data exist regarding the immune benefits of fourth COVID-19 vaccine doses in people with HIV (PWH) receiving antiretroviral therapy (ART), particularly now that most have experienced a SARS-CoV-2 infection. We quantified wild-type, Omicron-BA.5 and Omicron-BQ.1-specific neutralization up to 1 month post-fourth COVID-19 vaccine dose in 63 (19 SARS-CoV-2-naive and 44 SARS-CoV-2-experienced) PWH. DESIGN: A longitudinal observational cohort. METHODS: Quantification of wild-type-, Omicron-BA.5, and Omicron-BQ.1-specific neutralization using live virus assays. RESULTS: Participants received monovalent (44%) and bivalent (56%) mRNA fourth doses. In COVID-19-naive PWH, fourth doses enhanced wild-type and Omicron-BA.5-specific neutralization modestly above three-dose levels ( P  = 0.1). In COVID-19-experienced PWH, fourth doses enhanced wild-type specific neutralization modestly ( P  = 0.1) and BA.5-specific neutralization substantially ( P  = 0.002). Consistent with humoral benefits of 'hybrid' immunity, COVID-19-experienced PWH exhibited the highest neutralization post-fourth dose, wherein those with Omicron-era infections displayed higher wild-type specific ( P  = 0.04) but similar BA.5 and BQ.1-specific neutralization than those with pre-Omicron-era infections. Nevertheless, BA.5-specific neutralization was significantly below wild-type in everyone regardless of COVID-19 experience, with BQ.1-specific neutralization lower still (both P  < 0.0001). In multivariable analyses, fourth dose valency did not affect neutralization magnitude. Rather, an mRNA-1273 fourth dose (versus a BNT162b2 one) was the strongest correlate of wild-type specific neutralization, while prior COVID-19, regardless of pandemic era, was the strongest correlate of BA.5 and BQ.1-specific neutralization post-fourth dose. CONCLUSION: Fourth COVID-19 vaccine doses, irrespective of valency, benefit PWH regardless of prior SARS-CoV-2 infection. Results support recommendations that all adults receive a fourth COVID-19 vaccine dose within 6 months of their third dose (or their most recent SARS-CoV-2 infection).


Asunto(s)
COVID-19 , Infecciones por VIH , Adulto , Humanos , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Vacuna BNT162 , COVID-19/prevención & control , Vacunas contra la COVID-19 , Infecciones por VIH/complicaciones , Infecciones por VIH/tratamiento farmacológico , SARS-CoV-2
8.
Frontiers in immunology ; 13, 2022.
Artículo en Inglés | EuropePMC | ID: covidwho-2034121

RESUMEN

SARS-CoV-2 Omicron infections are common among individuals who are vaccinated or have recovered from prior variant infection, but few reports have immunologically assessed serial Omicron infections. We characterized SARS-CoV-2 humoral responses in an individual who acquired laboratory-confirmed Omicron BA.1.15 ten weeks after a third dose of BNT162b2, and BA.2 thirteen weeks later. Responses were compared to 124 COVID-19-naive vaccinees. One month post-second and -third vaccine doses, the participant’s wild-type and BA.1-specific IgG, ACE2-displacement and virus neutralization activities were average for a COVID-19-naive triple-vaccinated individual. BA.1 infection boosted the participant’s responses to the cohort ≥95th percentile, but even this strong “hybrid” immunity failed to protect against BA.2. Reinfection increased BA.1 and BA.2-specific responses only modestly. Though vaccines clearly protect against severe disease, results highlight the continued importance of maintaining additional protective measures to counteract the immune-evasive Omicron variant, particularly as vaccine-induced immune responses naturally decline over time.

9.
J Appl Lab Med ; 7(5): 1025-1036, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1901198

RESUMEN

BACKGROUND: To support the implementation of high-throughput pipelines suitable for SARS-CoV-2 sequencing and analysis in a clinical laboratory, we developed an automated sample preparation and analysis workflow. METHODS: We used the established ARTIC protocol with approximately 400 bp amplicons sequenced on Oxford Nanopore's MinION. Sequences were analyzed using Nextclade, assigning both a clade and quality score to each sample. RESULTS: A total of 2179 samples on twenty-five 96-well plates were sequenced. Plates of purified RNA were processed within 12 h, sequencing required up to 24 h, and analysis of each pooled plate required 1 h. The use of samples with known threshold cycle (Ct) values enabled normalization, acted as a quality control check, and revealed a strong correlation between sample Ct values and successful analysis, with 85% of samples with Ct < 30 achieving a "good" Nextclade score. Less abundant samples responded to enrichment with the fraction of Ct > 30 samples achieving a "good" classification rising by 60% after addition of a post-ARTIC PCR normalization. Serial dilutions of 3 variant of concern samples, diluted from approximately Ct = 16 to approximately Ct = 50, demonstrated successful sequencing to Ct = 37. The sample set contained a median of 24 mutations per sample and a total of 1281 unique mutations with reduced sequence read coverage noted in some regions of some samples. A total of 10 separate strains were observed in the sample set, including 3 variants of concern prevalent in British Columbia in the spring of 2021. CONCLUSIONS: We demonstrated a robust automated sequencing pipeline that takes advantage of input Ct values to improve reliability.


Asunto(s)
COVID-19 , Secuenciación de Nanoporos , Nanoporos , COVID-19/diagnóstico , COVID-19/epidemiología , Humanos , Reproducibilidad de los Resultados , SARS-CoV-2/genética
10.
J Infect Dis ; 226(6): 983-994, 2022 09 21.
Artículo en Inglés | MEDLINE | ID: covidwho-1840054

RESUMEN

BACKGROUND: Third coronavirus disease 2019 (COVID-19) vaccine doses are broadly recommended, but immunogenicity data remain limited, particularly in older adults. METHODS: We measured circulating antibodies against the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein receptor-binding domain, ACE2 displacement, and virus neutralization against ancestral and omicron (BA.1) strains from prevaccine up to 1 month following the third dose, in 151 adults aged 24-98 years who received COVID-19 mRNA vaccines. RESULTS: Following 2 vaccine doses, humoral immunity was weaker, less functional, and less durable in older adults, where a higher number of chronic health conditions was a key correlate of weaker responses and poorer durability. One month after the third dose, antibody concentrations and function exceeded post-second-dose levels, and responses in older adults were comparable in magnitude to those in younger adults at this time. Humoral responses against omicron were universally weaker than against the ancestral strain after both the second and third doses. Nevertheless, after 3 doses, anti-omicron responses in older adults reached equivalence to those in younger adults. One month after 3 vaccine doses, the number of chronic health conditions, but not age, was the strongest consistent correlate of weaker humoral responses. CONCLUSIONS: Results underscore the immune benefits of third COVID-19 vaccine doses, particularly in older adults.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Anciano , Enzima Convertidora de Angiotensina 2 , Anticuerpos Neutralizantes , Anticuerpos Antivirales , COVID-19/prevención & control , Humanos , ARN Mensajero , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus , Vacunas Sintéticas , Vacunas de ARNm
11.
NPJ Vaccines ; 7(1): 28, 2022 Feb 28.
Artículo en Inglés | MEDLINE | ID: covidwho-1713167

RESUMEN

Humoral responses to COVID-19 vaccines in people living with HIV (PLWH) remain incompletely characterized. We measured circulating antibodies against the SARS-CoV-2 spike protein receptor-binding domain (RBD), ACE2 displacement and viral neutralization activities one month following the first and second COVID-19 vaccine doses, and again 3 months following the second dose, in 100 adult PLWH and 152 controls. All PLWH were receiving suppressive antiretroviral therapy, with median CD4+ T-cell counts of 710 (IQR 525-935) cells/mm3, though nadir CD4+ T-cell counts ranged as low as <10 cells/mm3. After adjustment for sociodemographic, health and vaccine-related variables, HIV infection was associated with lower anti-RBD antibody concentrations and ACE2 displacement activity after one vaccine dose. Following two doses however, HIV was not significantly associated with the magnitude of any humoral response after multivariable adjustment. Rather, older age, a higher burden of chronic health conditions, and dual ChAdOx1 vaccination were associated with lower responses after two vaccine doses. No significant correlation was observed between recent or nadir CD4+ T-cell counts and responses to two vaccine doses in PLWH. These results indicate that PLWH with well-controlled viral loads and CD4+ T-cell counts in a healthy range generally mount strong initial humoral responses to dual COVID-19 vaccination. Factors including age, co-morbidities, vaccine brand, response durability and the rise of new SARS-CoV-2 variants will influence when PLWH will benefit from additional doses. Further studies of PLWH who are not receiving antiretroviral treatment or who have low CD4+ T-cell counts are needed, as are longer-term assessments of response durability.

12.
J Infect Dis ; 225(7): 1129-1140, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1566022

RESUMEN

BACKGROUND: The magnitude and durability of immune responses to coronavirus disease 2019 (COVID-19) mRNA vaccines remain incompletely characterized in the elderly. METHODS: Anti-spike receptor-binding domain (RBD) antibodies, angiotensin-converting enzyme 2 (ACE2) competition, and virus neutralizing activities were assessed in plasma from 151 health care workers and older adults (range, 24-98 years of age) 1 month following the first vaccine dose, and 1 and 3 months following the second dose. RESULTS: Older adults exhibited significantly weaker responses than younger health care workers for all humoral measures evaluated and at all time points tested, except for ACE2 competition activity after 1 vaccine dose. Moreover, older age remained independently associated with weaker responses even after correction for sociodemographic factors, chronic health condition burden, and vaccine-related variables. By 3 months after the second dose, all humoral responses had declined significantly in all participants, and remained significantly lower among older adults, who also displayed reduced binding antibodies and ACE2 competition activity towards the Delta variant. CONCLUSIONS: Humoral responses to COVID-19 mRNA vaccines are significantly weaker in older adults, and antibody-mediated activities in plasma decline universally over time. Older adults may thus remain at elevated risk of infection despite vaccination.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Anciano , Anticuerpos Neutralizantes , Anticuerpos Antivirales , COVID-19/prevención & control , Humanos , Inmunidad Humoral , Lactante , ARN Mensajero , SARS-CoV-2 , Vacunas Sintéticas , Vacunas de ARNm
13.
J Med Virol ; 93(12): 6808-6812, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: covidwho-1544312

RESUMEN

Real-time polymerase chain reaction (PCR) for SARS-CoV-2 is the mainstay of COVID-19 diagnosis, yet there are conflicting reports on its diagnostic performance. Wide ranges of false-negative PCR tests have been reported depending on clinical presentation, the timing of testing, specimens tested, testing method, and reference standard used. We aimed to estimate the frequency of discordance between initial nasopharyngeal (NP) PCR and repeat NP sampling PCR and serology in acutely ill patients admitted to the hospital. Panel diagnosis of COVID-19 infection is further utilized in discordance analysis. Included in the study were 160 patients initially tested by NP PCR with repeat NP sampling PCR and/or serology performed. The percent agreement between initial and repeat PCR was 96.7%, while the percent agreement between initial PCR and serology was 98.9%. There were 5 (3.1%) cases with discordance on repeat testing. After discordance analysis, 2 (1.4%) true cases tested negative on initial PCR. Using available diagnostic methods, discordance on repeat NP sampling PCR and/or serology is a rare occurrence.


Asunto(s)
COVID-19/diagnóstico , COVID-19/virología , Nasofaringe/virología , SARS-CoV-2/genética , Adulto , Prueba de COVID-19/métodos , Femenino , Humanos , Masculino , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Estándares de Referencia , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Sensibilidad y Especificidad , Manejo de Especímenes/métodos
14.
Emerg Infect Dis ; 27(11): 2802-2809, 2021 11.
Artículo en Inglés | MEDLINE | ID: covidwho-1357504

RESUMEN

Several severe acute respiratory syndrome coronavirus 2 variants of concern (VOCs) emerged in late 2020; lineage B.1.1.7 initially dominated globally. However, lineages B.1.351 and P.1 represent potentially greater risk for transmission and immune escape. In British Columbia, Canada, B.1.1.7 and B.1.351 were first identified in December 2020 and P.1 in February 2021. We combined quantitative PCR and whole-genome sequencing to assess relative contribution of VOCs in nearly 67,000 infections during the first 16 weeks of 2021 in British Columbia. B.1.1.7 accounted for <10% of screened or sequenced specimens early on, increasing to >50% by week 8. P.1 accounted for <10% until week 10, increased rapidly to peak at week 12, and by week 13 codominated within 10% of rates of B.1.1.7. B.1.351 was a minority throughout. This rapid expansion of P.1 but suppression of B.1.351 expands our understanding of population-level VOC patterns and might provide clues to fitness determinants for emerging VOCs.


Asunto(s)
COVID-19 , SARS-CoV-2 , Colombia Británica/epidemiología , COVID-19/epidemiología , COVID-19/virología , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa
16.
J Mol Diagn ; 23(8): 907-919, 2021 08.
Artículo en Inglés | MEDLINE | ID: covidwho-1248982

RESUMEN

Quantitative viral load assays have transformed our understanding of viral diseases. They hold similar potential to advance COVID-19 control and prevention, but SARS-CoV-2 viral load tests are not yet widely available. SARS-CoV-2 molecular diagnostic tests, which typically employ real-time RT-PCR, yield semiquantitative results only. Droplet digital RT-PCR (RT-ddPCR) offers an attractive platform for SARS-CoV-2 RNA quantification. Eight primer/probe sets originally developed for real-time RT-PCR-based SARS-CoV-2 diagnostic tests were evaluated for use in RT-ddPCR; three were identified as the most efficient, precise, and sensitive for RT-ddPCR-based SARS-CoV-2 RNA quantification. For example, the analytical efficiency for the E-Sarbeco primer/probe set was approximately 83%, whereas assay precision, measured as the coefficient of variation, was approximately 2% at 1000 input copies/reaction. Lower limits of quantification and detection for this primer/probe set were 18.6 and 4.4 input SARS-CoV-2 RNA copies/reaction, respectively. SARS-CoV-2 RNA viral loads in a convenience panel of 48 COVID-19-positive diagnostic specimens spanned a 6.2log10 range, confirming substantial viral load variation in vivo. RT-ddPCR-derived SARS-CoV-2 E gene copy numbers were further calibrated against cycle threshold values from a commercial real-time RT-PCR diagnostic platform. This log-linear relationship can be used to mathematically derive SARS-CoV-2 RNA copy numbers from cycle threshold values, allowing the wealth of available diagnostic test data to be harnessed to address foundational questions in SARS-CoV-2 biology.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , ARN Viral/genética , SARS-CoV-2/genética , COVID-19/virología , Humanos , Límite de Detección , ARN Viral/análisis , SARS-CoV-2/aislamiento & purificación , Carga Viral/métodos
18.
Emerg Infect Dis ; 27(6): 1673-1676, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: covidwho-1158332

RESUMEN

To screen all severe acute respiratory syndrome coronavirus 2-positive samples in Vancouver, British Columbia, Canada, and determine whether they represented variants of concern, we implemented a real-time reverse transcription PCR-based algorithm. We rapidly identified 77 samples with variants: 57 with B.1.1.7, 7 with B.1.351, and an epidemiologic cluster of 13 with B.1.1.28/P.1.


Asunto(s)
COVID-19 , SARS-CoV-2 , Colombia Británica/epidemiología , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa
19.
J Mol Diagn ; 23(6): 683-690, 2021 06.
Artículo en Inglés | MEDLINE | ID: covidwho-1121530

RESUMEN

Fast, accurate, and reliable diagnostic tests are critical for controlling the spread of the coronavirus disease 2019 (COVID-19) associated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. The current gold standard for testing is real-time PCR; however, during the current pandemic, supplies of testing kits and reagents have been limited. We report the validation of a rapid (30 minutes), user-friendly, and accurate microchip real-time PCR assay for detection of SARS-CoV-2 from nasopharyngeal swab RNA extracts. Microchips preloaded with COVID-19 primers and probes for the N gene accommodate 1.2-µL reaction volumes, lowering the required reagents by 10-fold compared with tube-based real-time PCR. We validated our assay using contrived reference samples and 21 clinical samples from patients in Canada, determining a limit of detection of 1 copy per reaction. The microchip real-time PCR provides a significantly lower resource alternative to the Centers for Disease Control and Prevention-approved real-time RT-PCR assays with comparable sensitivity, showing 100% positive and negative predictive agreement of clinical samples.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/normas , COVID-19/diagnóstico , Dispositivos Laboratorio en un Chip , ARN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , SARS-CoV-2/genética , Benchmarking , COVID-19/epidemiología , Prueba de Ácido Nucleico para COVID-19/instrumentación , Prueba de Ácido Nucleico para COVID-19/métodos , Canadá/epidemiología , Humanos , Límite de Detección , Nasofaringe/virología , Pruebas en el Punto de Atención , Juego de Reactivos para Diagnóstico/provisión & distribución
20.
Diagn Microbiol Infect Dis ; 100(1): 115324, 2021 May.
Artículo en Inglés | MEDLINE | ID: covidwho-1046489

RESUMEN

With surging global demand for SARS-CoV-2 testing capacity, laboratories seek automated, high-throughput molecular solutions, particularly for specimens not requiring specialized collection devices or viral transport media. Saliva specimens submitted from patients under investigation for COVID-19 from March to July 2020 were processed in the laboratory with sterile phosphate-buffered saline in a 1:2 dilution and tested using manual extraction and a commercial assay for detection of the SARS-CoV-2 E gene (LightMix®) in comparison to the Roche cobas® SARS-CoV-2 Test on the cobas® 6800 instrument. 34.4% (22/64) of saliva samples were positive for SARS-CoV-2. Positive and negative concordance between the LightMix® and cobas® assays were 100%. The overall invalid rate for saliva on the cobas® 6800 (1/128, 0.78%) was similar to the baseline invalid rate observed for nasopharyngeal swabs/viral transport media. Saliva is a feasible specimen type for SARS-CoV-2 testing on the cobas® 6800 platform, with potential to improve turnaround time and enhance testing capacity.


Asunto(s)
Prueba de COVID-19/métodos , Saliva/virología , Automatización de Laboratorios , Humanos , Técnicas de Diagnóstico Molecular , Manejo de Especímenes/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA